HOME ENERGY STORAGE / UNITED KINGDOM

Home storage.
Every detail considered.

LFP batteries and integrated storage for a carefully planned home installation. Match the architecture to your existing equipment, available utility space and selected household loads.

One home. A considered system.
Integrated storage or a battery for your inverter.

EU 230 V — INSTALLATION ILLUSTRATION
INSTALLATION ILLUSTRATION01 / 03
INSTALLATION ILLUSTRATION
INVERTER INCLUDEDEU 230 VIntegrated battery + inverter

SMALLER FOOTPRINT.
GREATER POSSIBILITIES.

07Product families
29Listed configurations
5.12–48 kWhNominal energy across the collection
Product tour

Product tour

One home. A considered system.

Integrated storage or a battery for your inverter.

RESIDENTIAL ENERGY STORAGE / UNITED KINGDOMLFP
All products

01 TWO WAYS TO STORE

Start with your setup.

A new installation or an existing inverter.
Choose your starting point.

TR PRO / MATERIAL & FORM
01 — ENCLOSURE / FRONT ELEVATIONPRODUCT DETAIL

03 LOOK A LITTLE CLOSER

Details you can
build around.

Start with the chemistry. Check the voltage. Specify the enclosure. Every good installation begins with a clear understanding of the product.

LiFePO₄
LFP battery chemistry
51.2 V
TR Pro nominal DC voltage
IP66
TR Pro enclosure rating
CAN / RS485
Communication interfaces
See TR Pro specifications

Plan for the room through every season.

UK conditions vary with region, elevation and exposure; the Met Office distinguishes generally warmer, drier conditions in the south and east from those farther north and west. The proposed equipment room needs a separate assessment.

01

Cooler winter location · unheated garage or outbuilding

An unheated garage in a colder or more exposed location can behave differently from a room within the occupied home. Use the actual expected temperature at the unit.

Check charging limits before selecting the location. TR Pro lists charging 0 to 55 °C and discharging −20 to 60 °C. Confirm any optional heating and charging protection; the lower discharge limit is not permission for subzero charging. HP Ultra limits must be confirmed for its exact configuration.

Can the battery position fall below 0 °C during charging?
  • Is any heating option included and confirmed for this model?
  • Can cold surfaces develop condensation as conditions change?
02

Detached or terraced home · dedicated utility space

Available floor area, access routes and separation from everyday storage matter when planning a dedicated equipment area in an existing home.

EU all-in-one combines battery and inverter in an IP21 enclosure and needs no extra inverter. Battery-only families need an external compatible inverter. Assess the exact manual's access, ventilation, mounting and project-specific placement requirements before choosing the room.

Can the proposed area be kept dry and clear for service?
  • Will access and required cooling space remain available?
  • Is this a new integrated installation or a battery addition to an existing inverter?
03

Seasonal damp or summer heat · assess the building

Regional climate is a starting point. A damp ancillary room or a sun-heated enclosed space can have conditions unlike nearby occupied rooms.

Record both the lowest and highest room temperatures, condensation and water-entry risks. IP66 does not on its own establish condensation, flood or coastal salt-spray suitability. Confirm enclosure, cooling and any high-temperature derating for the exact selected equipment.

Is there damp, a water-entry route or coastal exposure?
  • Does summer sun or roof heat raise the equipment-room temperature?
  • What placement and output limits apply to the exact configuration?
Specifications
  • Choose the architecture first: EU and TA6000 include an inverter. Battery-only TR, HP and TB families require a compatible external inverter with confirmed voltage, current and communication settings.
  • Check charging and discharging limits separately. Optional heating and a general operating-temperature field do not establish universal subzero charging; a maximum temperature does not promise full output at that temperature.
  • Use the exact enclosure rating and placement instructions. IP21, IP20, optional IP54 and IP66 are different source ratings; none alone establishes resistance to condensation, flooding or coastal salt spray.

02 THE COLLECTION

Storage. Clearly specified.

Seven families. Three installation formats.
Compare the details that matter.

3 product families

TR Pro.

Wall-mounted. Thoughtfully contained.

10.24 / 16.076 kWh

LFP battery storage in a wall-mounted format, with three specified models and an IP66 enclosure. Pair with a compatible external inverter.

Explore all product details ↗

EU 230 V.

An integrated starting point.

10.24 / 16.076 kWh

An integrated inverter and 51.2 V LFP battery system. Three listed power-and-capacity configurations, with rated AC output of 6.2 or 12 kW.

Explore all product details ↗

HP Ultra.

Storage with room to grow.

8–48 kWh

A modular aluminium-alloy LFP battery stack. Six specified configurations from 8 to 48 kWh, for integration with a compatible external inverter.

Explore all product details ↗

Confirm the selected configuration, project documentation, inverter compatibility and supply arrangements before ordering.

Your setup matters. Battery-only products require a compatible external inverter.

Download the full collection

PRODUCT DETAIL / ORIGINAL LITERATURE

Every side.
Every connection.

Look beyond the headline specifications. Explore original product views, labelled interfaces and details for each family.

05 KNOW YOUR ESSENTIALS

Explore
your backup.

Start with the essentials you want to keep running. Adjust the load and battery size to explore an indicative backup duration.

Battery energy is measured in kWh.
Appliance power is measured in kW.
Your inverter must support the load.

Inverter included in all-in-one systems; external for battery-only products.

BACKUP EXPLORERYOUR ESTIMATEWatt / kW
10.24 kWh
1.0 kW
0.2 kW5.0 kW
Illustrative planning allowances, not measured household averages or guaranteed runtime. Replace with actual simultaneous loads and check compressor starting demand, battery DC capability, inverter AC output and backup-capable circuits.
INDICATIVE BACKUP
8.3hours
How this estimate works

Nominal battery capacity × 90% assumed usable depth × 90% assumed inverter efficiency ÷ average load. These are planning assumptions, not guaranteed product ratings. Actual backup varies with usable energy, temperature, battery age, standby use and load changes. Starting currents and inverter limits must be checked separately.

Use this in my project

OUR PRODUCTS / AT HOME

Storage planned for the way your home works.

For UK homeowners and installation professionals planning storage in a detached house, a terrace or another suitable home: start with the space, system match and circuits that matter. These are application illustrations, not completed UK customer references.

EU 230 V / INVERTER INCLUDED

A dedicated place for storage.

Compare a new all-in-one installation with its inverter already integrated. Assess the proposed utility room, service access, ventilation and exact AC configuration for the property.

HP ULTRA / BATTERY ONLY

A battery for a compatible system.

Compare 51.2 V and high-voltage battery families against the exact external inverter's DC window, current limits and supported communications. Confirm the model and firmware pairing before selecting capacity.

TR PRO / BATTERY ONLY

A considered plan for essentials.

Identify the lighting, refrigeration, connectivity and work equipment to support. Check heat pumps, immersion heaters, electric cooking and EV charging separately from the indicative essential-load examples.

Installation illustrations featuring products from this collection. Scenes are composites, not photographs of completed customer projects. Visible layouts are illustrative; final connections, protection and clearances follow the selected model’s installation manual and site design.

06 KNOW YOUR SYSTEM

Choose with clarity.

elvorka product collectionEnglish · PDF · 8 pagesPDF
Original product collection · English PDF ↘

Good questions.
Straight answers.Start with the system you have.
Choose the storage you need.

What needs to be confirmed for a UK home battery installation?

Confirm the exact configuration, battery and inverter relationship, AC phase arrangement, charging-temperature limits, installation location and backup circuits. Required project documentation and country-specific suitability must be checked for the selected equipment; this catalogue does not establish certification or installation approval.

Can I connect a 51.2 V battery to my existing inverter?

A nominal voltage match alone does not confirm compatibility. Your installer should verify the inverter’s DC voltage window, charge and discharge current, CAN or RS485 protocol, firmware and protection settings. High-voltage batteries must not be connected to a low-voltage inverter.

What should be checked for a project in United Kingdom?

Confirm the installation’s AC supply, inverter phase requirements, essential-load circuits and local electrical requirements. The EU integrated range lists 230 V AC and 50 / 60 Hz. TA6000 lists 120 V US and 230 V EU options; specify the required market configuration. The project’s backup circuits and protection requirements need installer review.

Can these batteries be installed outdoors?

TR Pro and HP Ultra list IP66 enclosures. Other families have different or optional protection ratings. An IP rating alone is not an installation instruction: check the selected model’s temperature limits, clearances, shelter, ventilation and installer requirements.

Does more battery capacity mean more output power?

No. Capacity in kWh describes stored energy. Power in kW describes the rate energy can be delivered. Battery-side DC ratings and inverter AC output are different. Both the selected battery configuration and inverter must support your operating and starting loads.

How do I confirm price, warranty and availability?

Prepare a project brief with your city, required loads, existing inverter and selected product. Ask your supplier to confirm the exact configuration, quotation currency, warranty terms, installation scope, delivery timing and after-sales arrangements in writing.

Can I install a battery in an unheated garage?

Check the actual temperature, damp and exposure against the exact model's instructions. Several source families list charging from 0 °C. Confirm any heating configuration and charging protection; a colder discharge rating does not authorise charging below freezing.

Can the same battery back up a heat pump or immersion heater?

Assess these loads separately from the essentials examples. Running demand and compressor starting requirements can dominate the design. Confirm battery DC capability, inverter AC and backup output, and which circuits the project is designed to support.

Does the catalogue establish UK certification or compatibility?

No. Confirm the exact product configuration, required documentation and project-specific suitability, including inverter model and firmware when adding a battery. A nominal voltage, communication-port listing or generic product image is not evidence of a confirmed pairing or approval.

Your next chapter

Start with your setup.

YOUR NEXT CHAPTER

Let’s plan
your system.

Tell the story of your home. Prepare a clear project brief to share with your installer or storage supplier.

YOUR HOME. YOUR ENERGY.

Contact the Founder

eric@elvorka.com

Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry.

Your submitted details are saved for the ELVORKA team to review and follow up. Please avoid including passwords, identity documents or unrelated sensitive information.

ELVORKA

A clearer view of home storage.

Practical reading for choosing battery capacity, checking equipment-room conditions and preparing a useful installation brief.