TB rack

Low-voltage battery

TB rack.

Four specified LFP battery capacities for rack-mounted storage and a compatible external inverter.

INVERTER
Compatible external inverter required
ENCLOSURE
IP20
NOMINAL ENERGY
5.12–16.076 kWh
BATTERY VOLTAGE
51.2 V nominal DC
Start your project ↗

Specifications

Model / configurationEnergy (kWh)Rated DC (kW)
TB4000X5.125
TB6000X10.2410
TB8000X14.33610
TB8500X16.07610

Wi-Fi / Bluetooth is listed for TB6000X, TB8000X and TB8500X, excluding TB4000X. Power ratings are battery-side DC.

ModelDimensions (mm)Approx. kg
TB4000X482 × 178 × 420 / W × H × D42
TB6000X482 × 223 × 550 / W × H × D78
TB8000X482 × 223 × 710 / W × H × D109.5
TB8500X482 × 223 × 710 / W × H × D112

Communication: RS485 / CAN / RS232
Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C

Plan for the room through every season.

UK conditions vary with region, elevation and exposure; the Met Office distinguishes generally warmer, drier conditions in the south and east from those farther north and west. The proposed equipment room needs a separate assessment.

Temperature:
Charge 0 to 55 °C; discharge −20 to 60 °C
ENCLOSURE
IP20
01

Cooler winter location · unheated garage or outbuilding

An unheated garage in a colder or more exposed location can behave differently from a room within the occupied home. Use the actual expected temperature at the unit.

Check charging limits before selecting the location. TR Pro lists charging 0 to 55 °C and discharging −20 to 60 °C. Confirm any optional heating and charging protection; the lower discharge limit is not permission for subzero charging. HP Ultra limits must be confirmed for its exact configuration.

Can the battery position fall below 0 °C during charging?
  • Is any heating option included and confirmed for this model?
  • Can cold surfaces develop condensation as conditions change?
02

Detached or terraced home · dedicated utility space

Available floor area, access routes and separation from everyday storage matter when planning a dedicated equipment area in an existing home.

EU all-in-one combines battery and inverter in an IP21 enclosure and needs no extra inverter. Battery-only families need an external compatible inverter. Assess the exact manual's access, ventilation, mounting and project-specific placement requirements before choosing the room.

Can the proposed area be kept dry and clear for service?
  • Will access and required cooling space remain available?
  • Is this a new integrated installation or a battery addition to an existing inverter?
03

Seasonal damp or summer heat · assess the building

Regional climate is a starting point. A damp ancillary room or a sun-heated enclosed space can have conditions unlike nearby occupied rooms.

Record both the lowest and highest room temperatures, condensation and water-entry risks. IP66 does not on its own establish condensation, flood or coastal salt-spray suitability. Confirm enclosure, cooling and any high-temperature derating for the exact selected equipment.

Is there damp, a water-entry route or coastal exposure?
  • Does summer sun or roof heat raise the equipment-room temperature?
  • What placement and output limits apply to the exact configuration?
Specifications
  • Choose the architecture first: EU and TA6000 include an inverter. Battery-only TR, HP and TB families require a compatible external inverter with confirmed voltage, current and communication settings.
  • Check charging and discharging limits separately. Optional heating and a general operating-temperature field do not establish universal subzero charging; a maximum temperature does not promise full output at that temperature.
  • Use the exact enclosure rating and placement instructions. IP21, IP20, optional IP54 and IP66 are different source ratings; none alone establishes resistance to condensation, flooding or coastal salt spray.

PRODUCT DETAIL / ORIGINAL LITERATURE

Every side. Every connection.

The native front feature illustration and exploded callout illustration have visible layout differences and are not proven to be the same hardware revision. Keep each original view's source identity. The source has no external rear-view photograph. Internal/thermal diagrams must not be described as exterior rear or underside photos.

Original front terminal and control strip
Original front terminal and control stripFront terminal and control strip, with the negative terminal left and positive terminal right.
Negative power terminal, front left
Negative power terminal, front leftNegative terminal and minus mark at the front left.
Positive power terminal, front right
Positive power terminal, front rightPositive terminal and plus mark at the front right.
Original communication and control area
Original communication and control areaCommunication connectors, indicators and power switch on the front control strip.
Original cell and BMS construction detail
Original cell and BMS construction detailPartial internal illustration showing battery cells and the BMS board.

Know your interfaces.

Power connections

Positive power terminal
Power port on the viewer's right in the illustrated front panel, with the original plus mark.
Negative power terminal
Power port on the viewer's left in the illustrated front panel, with the original minus mark.

Communication

Dry Connect (source label)
Source names this a communication port labelled 'Dry Connect'. Contact logic, pinout and electrical ratings are not given.
COM0 / COM1 parallel ports
Ports explicitly captioned 'Parallel Port' in this source. Parallel-system limits and wiring are not supplied.
CAN / RS485
Communication port group named CAN/RS485. Appearance alone does not prove Ethernet networking or a compatible inverter protocol.
RS232
Communication port named RS232; exact pinout and adapter requirements are not provided.

Controls & indicators

Power switch
Power on/off switch as described in the original caption. Operating sequence is not supplied.
SOC / ALM / RUN indicators
Indicator-light group identified by the source. Individual colour meanings and diagnostic codes are not specified.
Address identification control
Control labelled 'Add'; the caption states automatic address identification. Setup method and address logic are not specified.

Structure & mounting

Laser welding
The brochure describes laser welding for the aluminium-plate and cell connection. It is an internal construction feature, not a port.
Steel holder
Internal steel holder identified as fixing the cells; not an external connector.
Plastic steel belt (source wording)
Cell-retaining band described in the source as preventing movement-related impacts; material performance is not independently validated.
Built-in smart BMS
Built-in BMS. The manufacturer lists temperature protection, short-circuit protection and balancing; this extraction does not independently verify those functions.
Portable handle
Steel handle as described in the source. It is not an electrical port.

Source: Residential ESS brochure · PDF page 7 · printed pages 13-14