# TR standard.

![TR standard](https://uk.elvorka.com/assets/optimized/54d556eb3b41e40a-1295-q92.webp)

Low-voltage battery

# TR standard.

Five specified capacities in a wall-mounted LFP battery format. Select the capacity, enclosure and a compatible external inverter for the installation.

INVERTER  Compatible external inverter required

ENCLOSURE  IP20; IP54 optional

NOMINAL ENERGY  5.12–20.07 kWh

BATTERY VOLTAGE  51.2 V nominal DC

[Start your project ↗](https://uk.elvorka.com/en/#enquiry)

## Specifications

| Model / configuration | Energy (kWh) | Nominal DC (V) |
| --- | --- | --- |
| TR4000WX | 5.12 | 51.2 |
| TR6000WX | 10.24 | 51.2 |
| TR8000WX | 14.336 | 51.2 |
| TR8500WX | 16.076 | 51.2 |
| TR10000WX | 20.07 | 51.2 |

Self-heating is optional. Confirm the charge/discharge current, output power and enclosure option for the exact model and inverter.

| Model | Dimensions (mm) | Approx. kg |
| --- | --- | --- |
| TR4000WX | 400 × 750 × 160 / W × H × D | 53.5 |
| TR6000WX | 600 × 750 × 160 / W × H × D | 95 |
| TR8000WX | 480 × 822 × 245 / W × H × D | 110 |
| TR8500WX | 480 × 822 × 245 / W × H × D | 115 |
| TR10000WX | 500 × 922 × 265 / W × H × D | 145 |

Communication: RS485 / RS232 / CAN; Wi-Fi / Bluetooth
Temperature: Charge 0 to 55 °C

## Plan for the room through every season.

UK conditions vary with region, elevation and exposure; the Met Office distinguishes generally warmer, drier conditions in the south and east from those farther north and west. The proposed equipment room needs a separate assessment.

Temperature:  Charge 0 to 55 °C

ENCLOSURE  IP20; IP54 optional

01

### Cooler winter location · unheated garage or outbuilding

An unheated garage in a colder or more exposed location can behave differently from a room within the occupied home. Use the actual expected temperature at the unit.

Check charging limits before selecting the location. TR Pro lists charging 0 to 55 °C and discharging −20 to 60 °C. Confirm any optional heating and charging protection; the lower discharge limit is not permission for subzero charging. HP Ultra limits must be confirmed for its exact configuration.

Can the battery position fall below 0 °C during charging?

- Is any heating option included and confirmed for this model?

- Can cold surfaces develop condensation as conditions change?

02

### Detached or terraced home · dedicated utility space

Available floor area, access routes and separation from everyday storage matter when planning a dedicated equipment area in an existing home.

EU all-in-one combines battery and inverter in an IP21 enclosure and needs no extra inverter. Battery-only families need an external compatible inverter. Assess the exact manual's access, ventilation, mounting and project-specific placement requirements before choosing the room.

Can the proposed area be kept dry and clear for service?

- Will access and required cooling space remain available?

- Is this a new integrated installation or a battery addition to an existing inverter?

03

### Seasonal damp or summer heat · assess the building

Regional climate is a starting point. A damp ancillary room or a sun-heated enclosed space can have conditions unlike nearby occupied rooms.

Record both the lowest and highest room temperatures, condensation and water-entry risks. IP66 does not on its own establish condensation, flood or coastal salt-spray suitability. Confirm enclosure, cooling and any high-temperature derating for the exact selected equipment.

Is there damp, a water-entry route or coastal exposure?

- Does summer sun or roof heat raise the equipment-room temperature?

- What placement and output limits apply to the exact configuration?

Specifications

- Choose the architecture first: EU and TA6000 include an inverter. Battery-only TR, HP and TB families require a compatible external inverter with confirmed voltage, current and communication settings.

- Check charging and discharging limits separately. Optional heating and a general operating-temperature field do not establish universal subzero charging; a maximum temperature does not promise full output at that temperature.

- Use the exact enclosure rating and placement instructions. IP21, IP20, optional IP54 and IP66 are different source ratings; none alone establishes resistance to condensation, flooding or coastal salt spray.

PRODUCT DETAIL / ORIGINAL LITERATURE

## Every side. Every connection.

Five model names provide family context, but the compact callout housing is not individually assigned to a SKU. The roller annotation expressly names TR8000WX and TR8500WX. Native photo detail is limited; no replacement surface or port detail is synthesized.

[![Front controls and side terminals](https://uk.elvorka.com/assets/product-details/tr-standard-controls-annotated.png)](https://uk.elvorka.com/assets/product-details/tr-standard-controls-annotated.png)

Front controls and side terminals  Touch screen, status indicators, communication ports and DC terminals on the illustrated cabinet.

[![Rear bracket and terminal-side labels](https://uk.elvorka.com/assets/product-details/tr-standard-rear-bracket-annotated.png)](https://uk.elvorka.com/assets/product-details/tr-standard-rear-bracket-annotated.png)

Rear bracket and terminal-side labels  Rear mounting bracket and side terminal area of the illustrated battery.

[![Circuit control switch detail](https://uk.elvorka.com/assets/product-details/tr-standard-switch-closeup.png)](https://uk.elvorka.com/assets/product-details/tr-standard-switch-closeup.png)

Circuit control switch detail  Circuit control switch with ON/OFF markings.

[![Original rear three-quarter view](https://uk.elvorka.com/assets/product-details/tr-standard-rear-threequarter.png)](https://uk.elvorka.com/assets/product-details/tr-standard-rear-threequarter.png)

Original rear three-quarter view  Rear three-quarter view showing the mounting bracket and terminal side.

[![Original side profile](https://uk.elvorka.com/assets/product-details/tr-standard-side-profile.png)](https://uk.elvorka.com/assets/product-details/tr-standard-side-profile.png)

Original side profile  Side profile showing communication ports and the recessed handle.

### Know your interfaces.

#### Power connections

Negative battery terminal  Negative DC battery power terminal as identified by the original arrow.

Positive battery terminal  Positive DC battery power terminal as identified by the original arrow.

#### Communication

Wi-Fi / Bluetooth  Wi-Fi/Bluetooth feature identified in the callout; no app or pairing workflow is established here.

Dry contact  Dry-contact interface identified; contact logic, pinout and electrical ratings are not supplied.

RS232 / CAN / RS485  Communications interfaces named in the source; protocol compatibility and wiring require separate confirmation.

COM0 / COM1  Ports named COM0/COM1. This page does not state their role, pinout or parallel-system limits.

#### Controls & indicators

Touch screen  Touch-screen display identified in the original callout.

Running status indicator  Running-status indication; source spelling is 'Runing Status'. Indicator logic is not specified.

Alarm indicator  Alarm indication identified in the source.

SOC indicator  SOC indicator identified in the source; display thresholds are not specified.

Reset control  Reset control identified by the source; operating procedure is not given on this page.

Battery switch  Battery switch identified in the source; no switching rating is given in this callout.

#### Structure & mounting

Folding handle  Mechanical folding handle; not an electrical connector.

Wall-mounted bracket  Wall-mounting bracket identified in the source; mounting load and fixing details are not supplied here.

Rollers  Rollers; the original annotation explicitly names TR8000WX and TR8500WX. Not an electrical interface.

Source: Residential ESS brochure · PDF page 3 · printed pages 5-6

---